These sensors mount on the Shuttle Board 3.0 connector described in Hardware: The ESP32-C5 and ESP-SensairShuttle. The ESP-SensairShuttle accepts interchangeable daughterboards:

  • BMI270 + BMM350 — six-axis inertial measurement and three-axis magnetic field sensing on one module.
  • BME690 — temperature, humidity, barometric pressure, and gas resistance.

BMI270 and BMM350 daughterboard
#

The motion shuttle board stacks a BMI270 IMU and BMM350 magnetometer on one Shuttle Board 3.0 module. Espressif routes the IMU to the ESP32-C5 over I²C (CS tied for I²C mode; address 0x68 or 0x69 from the SDO strap). The magnetometer is a separate I²C device (0x14 on this board with ADSEL grounded) and is often accessed through the BMI270 AUX I²C master for time-aligned 9-DoF data.

ShuttleBoard-BMI270 and BMM350 (front). Image source: Espressif ESP-Dev-Kits documentation.
Always disconnect power before handling the daughterboard. Before powering on the ESP-SensairShuttle, double-check that the daughterboard is correctly aligned and fully seated in its connector. Never connect, disconnect, or reposition the daughterboard while the mainboard is powered.
SensorFunctionUsed in this workshop?
BMI27016-bit triaxial accelerometer and gyroscope; up to 6.4 kHz gyro ODR; optional on-chip motion featuresYes — gyroscope at 200 Hz, ±2000 dps, 200-sample windows for the classifier
BMM35016-bit triaxial magnetometer (±2000 µT typ.); I²C/I³CNo — present on the daughterboard but not read by the gesture example

The BME690 is also not part of the gesture pipeline.

BMI270 — six-axis IMU
#

The BMI270 is a low-power 6-axis IMU that combines a digital triaxial accelerometer and triaxial gyroscope in one package. Bosch positions it for wearables, hearables, AR/VR, and activity recognition, with on-chip motion features (step counting, wrist-wear detection, gesture hints) that can run while the host sleeps.

Sensor channels
#

ChannelResolutionProgrammable full scale (typ.)
Accelerometer16-bit±2 g, ±4 g, ±8 g, ±16 g
Gyroscope16-bit±125, ±250, ±500, ±1000, ±2000 dps

Typical noise density is about 160 µg/√Hz on the accelerometer and 0.008 dps/√Hz on the gyroscope (performance mode targets lower gyro noise, below 7 mdps/√Hz in the datasheet summary). After soldering, gyro sensitivity can be trimmed with CRT (Component Re-Trimming) to roughly ±0.4% error when the device is stationary.

Output rate, filtering, and buffering
#

  • Accelerometer ODR: about 12.5 Hz to 1.6 kHz (datasheet); extended low rates down to 0.78 Hz are also available.
  • Gyroscope ODR: 25 Hz to 6.4 kHz.
  • Programmable low-pass filters on both channels (for example gyro bandwidth roughly 11 Hz to 751 Hz depending on ODR and mode).
  • 2 KB FIFO for accelerometer, gyroscope, auxiliary sensor, and timestamp data.

At full gyro ODR the part draws on the order of 685 µA (typical, aliasing-free operation). Supply range is 1.71 V to 3.6 V on VDD and 1.2 V to 3.6 V on VDDIO. The device comes in a 2.5 × 3.0 × 0.83 mm 14-pin LGA package and is pin-compatible with BMI160 and BMI260.

Host interfaces
#

The BMI270 exposes a primary digital interface (I²C or SPI) to the application processor and a configurable secondary interface:

  • I²C master (AUX) — connect one external I²C sensor (for example a magnetometer) with data hardware-synchronized to the IMU (sub-microsecond skew in the datasheet).
  • SPI (OIS) — optional high-speed path for optical image stabilization use cases.

FIFO and timestamping support time-aligned batches of IMU and AUX data on the primary interface, which simplifies 9-DoF fusion without polling two chips independently.

How the gesture example uses the BMI270
#

The ESP-SensairShuttle gesture recognition example configures the gyroscope for 200 Hz output and ±2000 dps range, then streams 200 consecutive three-axis samples (600 scalar values) into the TensorFlow Lite model. That window spans one second of motion at the chosen ODR.

Collection starts when the sum of absolute gyroscope readings exceeds a motion threshold (default 100 dps combined on x, y, and z). Values are converted to degrees per second before inference. The accelerometer is enabled for bring-up and other modes, but the classifier input is gyroscope-only.

BMM350 — three-axis magnetometer
#

The BMM350 is a 16-bit, three-axis magnetometer based on Bosch TMR (tunnel magnetoresistance) technology. It targets heading, compass, indoor navigation, AR/VR orientation, and robotics dead reckoning when paired with an IMU.

Compared with the earlier BMM150, Bosch cites roughly 3× better sensitivity and about 20× lower power in product materials. On the same daughterboard as the BMI270, the BMM350 completes a 9-DoF sensing set (gyro + accel + mag) for applications that need stable heading or map orientation.

Field performance and electrical data (typ.)
#

ParameterTypical value
Magnetic field range (x, y, z)±2000 µT
Field resolution~0.1 µT
Output noise (3 dB BW = ODR/2)±190 nT rms (x, y); ±450 nT rms (z)
Current @ 100 Hz (regular preset)200 µA
Max ODR (normal mode)400 Hz
Zero-field offset after soldering±25 µT
Gain error after soldering±1%
Operating temperature−40 °C to +85 °C

The part uses a 1.28 × 1.28 × 0.5 mm 9-pin WLCSP. VDD is 1.72 V to 1.98 V; VDDIO is 1.72 V to 3.6 V. Communication is I²C or I³C, with a data-ready interrupt on the INT pin (or in-band interrupt in I³C mode).

Operating modes
#

BMM350 supports normal, forced, and suspend modes. You can trade noise versus power through ODR and averaging presets; the Bosch sensor API rejects illegal setting combinations and picks the best noise performance for a valid configuration. Field shock recovery helps the sensor recover after exposure to strong fields (up to hundreds of millitesla) without the long-term drift seen on some competing parts.

Integration with the BMI270
#

On BMI270 + BMM350 shuttle modules, the magnetometer is typically reached through the IMU AUX I²C master: the ESP32 talks to the BMI270 on the main bus, and the BMI270 polls or streams BMM350 samples with IMU-aligned timestamps. This workshop does not read the BMM350; gesture classification relies on gyroscope dynamics only. For products that need compass-assisted rotation or drift control, the same hardware can feed fusion algorithms without changing the board.

Product documentation
#

Official Bosch sources for the specifications on this page:

Next step
#

Install ESP-IDF

Back to workshop home

WS004EN - This article is part of a series.
Part 3: This Article

Related